Order via WhatsAppCollection in Puchong, Selangor: collect your order from KLAE PLT, No. 53, Jalan Metro 1/1, Bandar Metro Puchong, 47160 Puchong, Selangor, Malaysia — or arrange your own courier or rider to collect it for you. Shipping & Collection Policy Payment: Pay online by FPX (online banking) through Billplz, or by bank transfer. Items in an unpaid order are reserved for 48 hours.
Description
With the MTL4016, two switches or proximity detectors located in a hazardous area can each control two safe-area loads. The four safe-area outputs are made through reed relays. Independent phase-reversal switches for each channel, located on top of the module, allow alarm signals to be signalled for either state of the sensors. Line-fault detection (LFD) for broken or shorted lines is provided, along with facilities for earth-fault detection. Power and switch status are indicated by LEDs on top of the module.
Specifications
| Number of channels | Two |
|---|---|
| Location of switches | Zone 0, IIC, T6 hazardous area Div.1, Group A, hazardous location |
| Location of proximity detector | Zone 0, IIC, T4–6 if suitably certified Div.1, Group A, hazardous location |
| Voltage applied to sensor | 7.0V – 9.0V dc from 1kΩ |
| Input/output characteristics | Outputs closed if >2.1mA (<2kΩ) in sensor circuit Outputs open if <1.2mA (>10kΩ) in sensor circuit Hysteresis: 200µA (650Ω) nominal |
| Phase reversal | The operation of each channel can be reversed by independent switches on top of the unit |
| Line fault detection (LFD) | Outputs open if input current <100µA (broken line) or >6.5mA (shorted lines) |
| 'No-fail' earth fault protection | Enabled by connecting terminals 3 and 6 to an MTL4220 earth leakage detector Fault on either line of each channel proclaimed: unit continues working |
| Relay output characteristics | Double-pole on/off, open when relay de-energised Response time: 2ms maximum Contact rating: 10W, 0.5A, 35V (dc) Contact life expectancy: 10⁶ operations at maximum load |
| LED indicators | Amber: one provided for each channel, ON when output circuit is closed Green: one provided for power indication |
| Power requirement (Vs) | 50mA at 24V dc 60mA at 20V dc 45mA at 35V dc |
| Power dissipation within unit | 1.2W at 24V 1.6W at 35V |
| Isolation | 250V ac between safe and hazardous area circuits |
| Safety description for each channel | 10.5V, 800Ω, 14mA |
| FM entity parameters | Voc = 10.5V dc, Isc = 14mA, Ca = 2.4µF, La = 165mH |