Skip to main content
KLAE PLT
MTL4024 Solenoid/Alarm Driver, 24V

Industrial Control & Instrumentation

MTL4024 Solenoid/Alarm Driver, 24V

Brand:
Eaton/MTL
Model:
4024
New No warranty — sold as-is

RM 335.40

10 units available

Enquire First
Order via WhatsApp

Collection in Puchong, Selangor: collect your order from KLAE PLT, No. 53, Jalan Metro 1/1, Bandar Metro Puchong, 47160 Puchong, Selangor, Malaysia — or arrange your own courier or rider to collect it for you. Shipping & Collection Policy Payment: Pay online by FPX (online banking) through Billplz, or by bank transfer. Items in an unpaid order are reserved for 48 hours.

Description

The MTL4024 (loop powered, for 24V systems) enables an on/off device in a hazardous area to be controlled by a 24V signal in the safe area. It can drive loads such as solenoids, alarms, LEDs and other low-power devices that are certified as intrinsically safe or classified as non-energy-storing simple apparatus. Provided that 24V dc is applied to the override input, the solenoid/alarm can be operated by a voltage change in the safe area; if the 24V dc override signal is removed, the solenoid/alarm turns off. Earth-fault detection can be provided by connecting an MTL4220 earth leakage detector to terminal 6.

Specifications

Number of channels One
Location of signal load Zone 0, IIC, T4–6 hazardous area if suitably certified Div.1, Group A, hazardous location
Maximum output voltage 25.5V from 232Ω
Output ripple <0.5% of maximum output, peak-to-peak
Override input A 24V signal applied across terminals 8 and 9 allows the solenoid/alarm to be operated by the supply across terminals 10 and 11. If the 24V signal is disconnected, the solenoid/alarm is off. <2.0V: Off >9.0V: Controlled by supply across terminals 10 and 11 >2.0V but <9.0V: Undetermined
Input impedance at terminal 8 Typically 10kΩ
Response time Output within 10% of final value within 100ms
'No-fail' earth fault protection Enabled by connecting terminal 6 to an MTL4220 earth leakage detector Fault on either line proclaimed: unit continues working
LED indicators Amber: one provided for status, ON when output circuit is active Green: one provided for drive status, ON when supply is connected
Power requirement (control) 100mA at 24V dc 120mA at 20V dc 75mA at 35V dc
Power dissipation within unit 1.3W at 24V with typical solenoid valve, output on 1.9W worst case
Isolation 250V ac between safe- and hazardous-area circuits
Safety description 25.5V, 232Ω, 110mA
FM entity parameters Voc = 25.5V dc, Isc = 110mA, Ca = 0.17µF, La = 3mH