MTL4032 Pulse Input
- Brand:
- Eaton/MTL
- Model:
- 4032
RM 201.30
Only 1 left in stock
Order via WhatsAppCollection in Puchong, Selangor: collect your order from KLAE PLT, No. 53, Jalan Metro 1/1, Bandar Metro Puchong, 47160 Puchong, Selangor, Malaysia — or arrange your own courier or rider to collect it for you. Shipping & Collection Policy Payment: Pay online by FPX (online banking) through Billplz, or by bank transfer. Items in an unpaid order are reserved for 48 hours.
Description
The MTL4032 pulse isolator isolates pulses from a switch, proximity detector, current pulse transmitter or voltage pulse transmitter located in a hazardous area. It is ideal for applications involving high pulse rates and fast response times.
Specifications
| Number of channels | One, fully floating |
|---|---|
| Sensor type | Switch or proximity detector (NAMUR/DIN 19234) 2- or 3-wire voltage or pulse transmitter |
| Location of switch | Zone 0, IIC, T6 hazardous area Div.1, Group A, hazardous location |
| Location of proximity detector or transmitter | Zone 0, IIC, T4–T6 if suitably certified Div.1, Group A, hazardous location |
| Switch input | Output ON if switch is closed Output OFF if switch is open |
| Proximity detector input | Excitation: 7.0 to 9.0V dc from 1kΩ nominal Output ON if input >2.1mA (<2kΩ) Output OFF if input <1.2mA (>10kΩ) Switching hysteresis: 0.2mA (650Ω) nominal |
| Current pulse input | Transmitter supply: 16.5V dc at 20mA Short circuit current: 24mA Output ON if input >9.0mA Output OFF if input <7.0mA Switching hysteresis: 0.5mA |
| Voltage pulse input | Input impedance: >10kΩ Switching point voltage (Vsp): 3, 6, or 12V nominal (selectable by switch on top of unit) Output ON if input >Vsp Output OFF if input <Vsp Switching hysteresis: 100mV + (0.1 x Vsp) typical |
| Pulse width | High: 10µs min Low: 10µs min |
| Frequency range | 0–50kHz |
| Output characteristics | Maximum off-state voltage: 35V Maximum off-state leakage current: 10µA Maximum on-state voltage drop: 1 + (0.1x current in mA) V Maximum on-state current: 50mA Output OFF if supply fails |
| Power requirement | 65mA at 24V dc 70mA at 20V dc 55mA at 35V dc |
| Power dissipation within unit | 1.35W maximum at 24V 1.75W maximum at 35V |
| Isolation | 250V ac between safe- and hazardous-area circuits |
| Safety description | Terminals 2 to 1: 10.5V, 800Ω, 14mA Terminals 4 to 3 and 1: 28V, 300Ω, 93mA Terminals 3 to 1: non-energy storing apparatus ≤1.2V, ≤0.1A, ≤20µJ and ≤25mW Terminals 5 to 4 and 1: Vmax ≤28V, Imax ≤94mA, Pmax ≤0.66W |